# kttl — Analog Control Prototype Wiring (LM35 sensor)
|
||
|
||
Fully-analog temperature controller for a kettle, styled after a Soviet
|
||
radiometer panel. No MCU: a comparator loop reaches/holds a rotary-selected
|
||
target, a moving-coil meter shows live temperature on a **linear 0–100 °C
|
||
dial**, and a solenoid-struck keyswitch clicks (Geiger-style) on each heater
|
||
cycle.
|
||
|
||
Sensor is an **LM35** (10 mV/°C, linear) — chosen so the dial is truly linear
|
||
and the setpoint ladder is evenly spaced.
|
||
|
||
> **Status:** prototype / paper design. A few values depend on measuring the
|
||
> actual meter movement and solenoid — see *Open Unknowns*.
|
||
|
||
---
|
||
|
||
## 1. Panel controls
|
||
|
||
| Ref | Control | Type | Function | Domain |
|
||
|-----|--------------------|----------------------|-------------------------------------------|-------------|
|
||
| SW1 | Rotary selector | 6-position, 1 wafer | Target temp tap (60/70/80/85/90/100 °C) | low-voltage |
|
||
| SW2 | Rocker (on/off) | SPST | **Heater enable only** (not master power) | low-voltage |
|
||
| SW3 | Hold toggle | SPDT | After target: HOLD (cycle) vs ONE-SHOT | low-voltage |
|
||
| M1 | Moving-coil meter | µA/mA movement (М205)| Live temperature, linear 0–100 °C | always-on |
|
||
|
||
Mains is live whenever plugged in. Electronics + meter sit on an **always-on
|
||
rail**; the heater is gated downstream and switched only by the relay/SSR
|
||
(mains-last). The rocker just **stops heating** — it is not a master cut-off.
|
||
|
||
---
|
||
|
||
## 2. Power tree
|
||
|
||
```
|
||
MAINS (live when plugged in)
|
||
├─────────► PSU (mains→5V, always on) ──► +5V rail ─┬─► LM35, comparator, latch,
|
||
│ │ meter driver, clicker logic
|
||
│ └─► VREF_PRECISE (LM4040-2.5)
|
||
│ → setpoint ladder
|
||
│
|
||
└─► HEATER PATH (mains): F1 fuse ─► TC1 thermal cutoff ─► K1/SSR1 ─► ELEMENT
|
||
▲
|
||
enable = SW2(rocker) AND logic-heat
|
||
```
|
||
|
||
**Note:** the ladder reference is now a **precision reference (not ratiometric)**
|
||
because the LM35 output is an absolute voltage (10 mV/°C). The 5 V rail no longer
|
||
needs to be accurate, but VREF_PRECISE does.
|
||
|
||
---
|
||
|
||
## 3. Schematic (block + signal level)
|
||
|
||
```
|
||
+5V (always on) VREF_PRECISE = 2.500V (LM4040-2.5)
|
||
│ │
|
||
┌──────┴──────┐ ┌────────┴────────┐
|
||
│ LM35 │ OUT = 10mV/°C │ SETPOINT LADDER │
|
||
│ Vs OUT GND│ (0°C=0V, 100°C=1.00V) │ R1..R7 (taps=°C)│
|
||
└───┬───┬───┬──┘ └────────┬────────┘
|
||
│ │ └─GND │ taps: 0.60/0.70/0.80/
|
||
│ │ │ 0.85/0.90/1.00 V
|
||
│ ├─────────────┬──────────────┐ ┌───────┴───────┐
|
||
│ │ │ │ │ SW1 rotary 6-pos│
|
||
[Rpd 18k │ │ └───────┬───────┘
|
||
to GND] (to meter (to comparator −) │ common = selected Vref
|
||
│ driver U3) │ R_in 10k │
|
||
GND │ │ │
|
||
▼ ▼ │
|
||
┌──────────────────────┐ │
|
||
│ U1 COMPARATOR LM393 │ │ Rf 2.4M
|
||
│ (−) LM35 (+) tap │◄─┴──── hysteresis
|
||
│ OUT ├──┬──── (to +) ~±1°C
|
||
└──────────────────────┘ │
|
||
OUT HIGH = cold │ on→off edge = "reached"
|
||
(pull-up 10k to +5V) │
|
||
┌──────────────────────────────┴──┐
|
||
│ │
|
||
▼ ▼
|
||
┌──────────────┐ ┌────────────────┐
|
||
│ U2 CD4013 │ │ CLICKER one-shot│
|
||
│ D-FF latch │ │ → Q1 MOSFET │
|
||
│ D=Hi │ │ → L1 solenoid │
|
||
│ CLK=reached │ │ (+ D1 flyback)│
|
||
│ CLR=POR + SW1│ │ strikes keyswitch│
|
||
│ Q' ───┼──┐ └────────────────┘
|
||
└──────────────┘ │
|
||
▼
|
||
SW3 HOLD ──────► ┌───────────────┐
|
||
(HOLD: force Hi; │ ENABLE gate │
|
||
1-SHOT: use Q') │ (AND) │
|
||
└──────┬────────┘
|
||
│ heater-want
|
||
SW2 rocker (series)
|
||
│
|
||
▼
|
||
┌──────────────┐
|
||
│ Q2 ─► K1/SSR1│ switches MAINS to ELEMENT
|
||
└──────┬───────┘ (via F1 + TC1, mains-last)
|
||
▼
|
||
ELEMENT
|
||
|
||
METER BRANCH:
|
||
LM35 OUT ─► U3 (op-amp + transistor current sink, Re) ─► M1
|
||
I_meter = V_LM35 / Re (no offset: 0°C = 0V)
|
||
linear 0–100 °C dial
|
||
```
|
||
|
||
---
|
||
|
||
## 4. Component values
|
||
|
||
### 4.1 Sensor — LM35
|
||
- **U_LM35:** LM35 (or LM35DZ), Vs = +5 V, OUT = 10 mV/°C.
|
||
- 0 °C → 0.000 V, 60 °C → 0.600 V, 100 °C → 1.000 V.
|
||
- **Rpd:** ~18 kΩ from OUT to GND (lets the output pull down toward 0 V; basic
|
||
LM35 only *sources* current). True 0 °C reading needs a negative rail; with a
|
||
GND pull-down it reads reliably from ~+2 °C up — fine for a kettle.
|
||
- Seal the sensor against water/steam (it's a 3-pin active part, not a bead).
|
||
|
||
### 4.2 Precision reference + setpoint ladder
|
||
- **VREF_PRECISE:** LM4040-2.5 (2.500 V shunt reference) + bias resistor from
|
||
+5 V (e.g. ~2.7 kΩ). Absolute accuracy now matters (not ratiometric).
|
||
- Ladder GND → 2.500 V; SW1 taps land on the LM35 setpoint voltages:
|
||
|
||
| Ref | Segment | Calc. | Use (E96/std) |
|
||
|-----|----------------------|---------|---------------|
|
||
| R1 | GND → 60 °C (0.60 V) | 6.00 kΩ | 6.04 kΩ |
|
||
| R2 | 60 → 70 °C | 1.00 kΩ | 1.00 kΩ |
|
||
| R3 | 70 → 80 °C | 1.00 kΩ | 1.00 kΩ |
|
||
| R4 | 80 → 85 °C | 0.50 kΩ | 499 Ω |
|
||
| R5 | 85 → 90 °C | 0.50 kΩ | 499 Ω |
|
||
| R6 | 90 → 100 °C | 1.00 kΩ | 1.00 kΩ |
|
||
| R7 | 100 °C (1.00 V) → ref| 15.0 kΩ | 15.0 kΩ |
|
||
| RT | master cal trim | — | 500 Ω 10-turn (series w/ R7) |
|
||
|
||
Ladder current ≈ 100 µA. Setpoint voltages = temp × 10 mV/°C — clean and even.
|
||
|
||
### 4.3 Comparator + hysteresis
|
||
- **U1:** LM393. LM35 OUT → (−); SW1 tap → (+) via **R_in = 10 kΩ**.
|
||
OUT HIGH = cold = heater wanted. Pull-up 10 kΩ on OUT to +5 V.
|
||
- **Rf:** 2.4 MΩ from OUT to (+) → maintain band ≈ ±1 °C (R_in/Rf · Vout_swing).
|
||
Band varies slightly with selected tap impedance.
|
||
|
||
### 4.4 Mode latch (one-shot vs hold)
|
||
- **U2:** CD4013 D flip-flop. D = HIGH. CLK = comparator on→off ("reached") edge
|
||
(RC-debounce if it chatters). CLR = power-on-reset cap **and** SW1 common
|
||
(changing temp re-arms). Q′ → enable gate.
|
||
- **SW3 (Hold):**
|
||
- HOLD → forces enable gate's 2nd input HIGH (latch bypassed → cycles forever).
|
||
- ONE-SHOT → enable uses Q′ (heater latches OFF after first reach).
|
||
- Wire SW3 to also pulse CLR so flipping to HOLD resumes cycling.
|
||
|
||
### 4.5 Heater drive
|
||
- Enable gate (heater-want) AND **SW2 rocker** (series) → **Q2** (small MOSFET) →
|
||
relay coil **K1** (with flyback diode) *or* **SSR1** control input.
|
||
- K1/SSR1 switches mains to the element, downstream of **F1 (fuse)** and **TC1
|
||
(independent thermal cutoff)**.
|
||
|
||
### 4.6 Clicker
|
||
- Comparator on→off edge → one-shot pulse → **Q1** (logic-level MOSFET) → **L1**
|
||
mini push-pull solenoid (5 V, ~3.5 mm stroke, Adafruit 2776 class) + **D1**
|
||
flyback diode. Plunger strikes a tactile keyswitch (switch gives the click +
|
||
bump; pick the strike target/resonator for pitch).
|
||
- HOLD → ticks each maintain cycle; ONE-SHOT → single tick. Add jitter to the
|
||
pulse for Geiger-style randomness instead of metronomic ticking.
|
||
|
||
### 4.7 Meter driver
|
||
- **U3:** op-amp + transistor current sink. LM35 OUT → op-amp (+); meter in the
|
||
collector/drain; Re in emitter/source. `I_meter = V_LM35 / Re`, independent of
|
||
coil resistance. **No offset stage** (0 °C already = 0 V).
|
||
- Re by movement: **1 mA → Re = 1.00 kΩ**; **100 µA → Re = 10.0 kΩ**.
|
||
- Dial is **linear 0–100 °C** — re-letter the М205 face 0→100.
|
||
|
||
---
|
||
|
||
## 5. Safety notes
|
||
- **SW1/SW2/SW3 are all low-voltage.** No panel switch carries element current;
|
||
mains is switched only by K1/SSR1 (mains-last).
|
||
- **F1 fuse + TC1 thermal cutoff in series with the element are mandatory.** The
|
||
comparator/latch is *control*, not *protection* — it can't save you from a
|
||
welded relay or a failed/detached sensor.
|
||
- **Always-on rail = always-live internals.** True off is unplugging; the rocker
|
||
only stops heating.
|
||
- Keep the meter/logic rail decoupled from heater switching transients, or the
|
||
needle twitches and the latch can glitch each cycle.
|
||
|
||
---
|
||
|
||
## 6. Open unknowns (measure before committing values)
|
||
1. **М205 movement:** full-scale current and coil resistance — sets Re. Measure
|
||
first; guess wrong and the needle pins or barely moves.
|
||
2. **Solenoid force/stroke** vs the chosen keyswitch (~0.5 N, ~2 mm): confirm
|
||
force *at* the working stroke (not headline force) and intermittent duty at
|
||
the fastest click rate (near boil).
|
||
3. **LM35 low-end:** reads down to ~+2 °C with a GND pull-down; true 0 °C needs a
|
||
negative supply. Decide if that matters for the dial's bottom mark.
|
||
4. **Sensor sealing/placement:** the LM35 must be waterproofed; element-mounted
|
||
(fast, overshoots) vs water-immersed (accurate, laggy) changes hysteresis feel.
|
||
5. **VREF_PRECISE accuracy** now sets setpoint accuracy directly (no ratiometric
|
||
cancellation) — use a ≤0.5% reference and the master trim RT to null offset.
|
||
```
|